Compare akfldms industrial control board 2-ch relay rs485 interface relay modbus rtu protocol control optocoupler isolation products from over 5,000 stores

Akfldms Industrial Control Board 2-CH Relay RS485 Interface Relay Modbus RTU Protocol Control Optocoupler Isolation

We currently have no offers for this products

2. The board is equipped with and stable 8bit MCU and SP3485 level conversion chip. 1. This design is a relay for industrial application scenarios. It uses Modbus RTU protocol control and 485 signal as the transmission mode. It supports multiple devices controlled by the same host. It can be well applied to industrial automation. With ABS shell and rail buckle, it can be better used in actual environment. 3. Wiring instructions: The relay can be assigned an address in the 485 bus, ranging from 1-255. The corresponding instructions can be sent for the address of the relay, so that the relay receiving the instruction can open and close any controlled circuit. 4. Note: When the relay is energized, the COM terminal and the NO terminal are connected and disconnected from the NC terminal. That is, load 1 works and load 2 does not work. When the relay is not energized or not connected to the power supply, the COM terminal and the NC terminal are connected and disconnected from the NO terminal. That is, load 2 works and load 1 does not work., Manufacturer: Akfldms

Akfldms Industrial Control Board 2-CH Relay RS485 Interface Relay Modbus RTU Protocol Control Optocoupler Isolation

2. The board is equipped with and stable 8bit MCU and SP3485 level conversion chip. 1. This design is a relay for industrial application scenarios. It uses Modbus RTU protocol control and 485 signal as the transmission mode. It supports multiple devices controlled by the same host. It can be well applied to industrial automation. With ABS shell and rail buckle, it can be better used in actual environment. 3. Wiring instructions: The relay can be assigned an address in the 485 bus, ranging from 1-255. The corresponding instructions can be sent for the address of the relay, so that the relay receiving the instruction can open and close any controlled circuit. 4. Note: When the relay is energized, the COM terminal and the NO terminal are connected and disconnected from the NC terminal. That is, load 1 works and load 2 does not work. When the relay is not energized or not connected to the power supply, the COM terminal and the NC terminal are connected and disconnected from the NO terminal. That is, load 2 works and load 1 does not work., Manufacturer: Akfldms

We currently have no offers for this products

This site contains affiliate links for which we may be compensated.

Similar Products

Abb Ot Control Knob For Power Switch - 1Sca108252r1001

Tameson UK

£10.57

View All
Finder 48.52 Interface Relay Module 8A 230Vac - 48.52.8.230.0060

Tameson UK

£18.78

Siemens ST70-1200 Digital SM 1223 8 Module Input 8 Output Transistor 0.5A

Amazon

£216.80

Siemens Simatic Plc Analog Input And Output Module - 6Es72314hf320xb0

Tameson UK

£495.20