Pokfhgur Rs485 Modbus Relay Pro Rs485 Interface Relay Modbus Rtu Protocol Control Optocoupler Isolation

£13.85

3. Wiring instructions: The relay can be assigned an address in the 485 bus, ranging from 1-255. The corresponding instructions can be sent for the address of the relay, so that the relay receiving the instruction can open and close any controlled circuit. 2. The board is equipped with and stable 8bit MCU and SP3485 level conversion chip. 1. This design is a relay for industrial application scenarios. It uses Modbus RTU protocol control and 485 signal as the transmission mode. It supports multiple devices controlled by the same host. It can be well applied to industrial automation. With ABS shell and rail buckle, it can be better used in actual environment. 4. Note: When the relay is energized, the COM terminal and the NO terminal are connected and disconnected from the NC terminal. That is, load 1 works and load 2 does not work. When the relay is not energized or not connected to the power supply, the COM terminal and the NC terminal are connected and disconnected from the NO terminal. That is, load 2 works and load 1 does not work., Manufacturer: PokFhgur

Pokfhgur Rs485 Modbus Relay Pro Rs485 Interface Relay Modbus Rtu Protocol Control Optocoupler Isolation

3. Wiring instructions: The relay can be assigned an address in the 485 bus, ranging from 1-255. The corresponding instructions can be sent for the address of the relay, so that the relay receiving the instruction can open and close any controlled circuit. 2. The board is equipped with and stable 8bit MCU and SP3485 level conversion chip. 1. This design is a relay for industrial application scenarios. It uses Modbus RTU protocol control and 485 signal as the transmission mode. It supports multiple devices controlled by the same host. It can be well applied to industrial automation. With ABS shell and rail buckle, it can be better used in actual environment. 4. Note: When the relay is energized, the COM terminal and the NO terminal are connected and disconnected from the NC terminal. That is, load 1 works and load 2 does not work. When the relay is not energized or not connected to the power supply, the COM terminal and the NC terminal are connected and disconnected from the NO terminal. That is, load 2 works and load 1 does not work., Manufacturer: PokFhgur

Price now:

£13.85

£13.85

Amazon

Shop

Similar Products

Pokfhgur Rs485 Modbus Relay Pro Rs485 Interface Relay Modbus Rtu Protocol Control Optocoupler Isolation

Amazon

£13.85

£13.97

View All
Pokfhgur Wall-Mounted Temperature And Humidity Transmitter Sensor Rs485 Modbus With Display Track Installation

Amazon

£34.46

£34.75

Pokfhgur Rs485 Temperature Humidity Sensor Modbus Rtu Temp Sensor Digital Industrial Temp And Humidity Transmitter Wall Mounted

Amazon

£34.19

PokFhgur 2X Temperature Humidity Transmitter RS485 SHT20 Sensor Modbus RTU Acquisition Module Transducer High

Amazon

£15.37

Pokfhgur Temperature Acquisition Module 8 Way Modbus Rs485 Type K Thermocouple Input Gateway Watchdog Industrial

Amazon

£33.64